Nortel Networks Nortel Secure Network Access Switch 4050 Manuel d'utilisateur Page 854

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 922
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 853
854 Appendix B Syslog messages
320818-A
Table 191 lists the System Control Process INFO messages.
About alarm messages
Alarms are sent at a syslog level corresponding to the alarm severity shown in
Table 192.
Alarms are formatted according to the following pattern:
Id: <alarm sequence number>
Severity: <severity>
Name: <name of alarm>
Time. <date and time of the alarm>
Sender: <sender, e.g. system or the Nortel SNAS 4050 device’s IP address>
Cause: <cause of the alarm>
Extra: <additional information about the alarm>
When an alarm is cleared, one of the following messages is sent:
Alarm Cleared Name=“<Name>” Id= “<ID>” Sender=“<Sender>”
Alarm Cleared Id=“<ID>”
Table 191
System control process messages — INFO
Message Category Explanation/Action
System started [isdssl-<version>] INFO Sent whenever the system control process has been
(re)started.
Table 192 Alarm severity and syslog level correspondence
Alarm severity Syslog level
CRITICAL ALERT
MAJOR CRITICAL
MINOR ERROR
WARNING WARNING
*ERROR
Vue de la page 853
1 2 ... 849 850 851 852 853 854 855 856 857 858 859 ... 921 922

Commentaires sur ces manuels

Pas de commentaire