Chapter 12 Configuring SNMP 629
Nortel Secure Network Access Switch 4050 User Guide
addmonitor
[<options>] -t <name>
<OID> <value and
event>
Adds a threshold monitor and trigger as defined in the
DISMAN-EVENT-MIB.
Valid <
options> are:
-c <comment> — adds a comment
-f <frequency> — the sampling interval, in
seconds. The default is 600 (10 minutes).
-o <OID> — additional objects to send in the
event
-d <OID> — the delta discontinuity OID
-D timeTicks|timeStamp|dateAndTime
— the delta discontinuity type
Other parameters are:
name — a unique name you assign to the monitor,
for identification
OID — the object identifier (or symbolic name) to
monitor
value and event — a combination of an
integer and an event condition, where the integer
represents the event condition threshold that will
trigger notification. Valid combinations are:
<LowVal> FallingEvent
<HighVal> RisingEvent
<DeltaLowVal> DeltaFallingEvent
<DeltaHighVal> DeltaRisingEvent
/cfg/sys/adm/snmp/event