Nortel Networks 10BASE-T Manuel d'utilisateur Page 159

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 330
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 158
Using the Console Interface
309985-C Rev 00
3-17
sysObjectID
A read-only field that provides a unique identification of the switch, which contains the
vendors private enterprise number.
sysUpTime
A read-only field that shows the length of time since the last reset. Note that this field
is updated when the screen is redisplayed.
sysServices
A read-only field that indicates the switchs physical and data link layer functionality.
sysContact
The name and phone number of the person responsible for the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters
1
sysName
A name that uniquely identifies the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters
1
sysLocation
The physical location of the switch.
Default Zero-length string
Range Any ASCII string of up to 56 printable characters
1 Although this field can be set to up to 255 characters from a Network Management Station (NMS), only 56 characters
are displayed on the console terminal.
Table 3-4. System Characteristics Screen Fields
(continued)