Installing the BayStack 410-24T Switch
309985-C Rev 00
2-11
Connecting a Terminal to the Console/Comm Port
To connect a terminal to the Console/Comm port:
1.
Set the terminal protocol as described in Console/Comm Port on
page 2-10
.
2.
Connect the terminal (or a computer in terminal-emulation mode) to the
console port using the RS-232 cable.
3.
Connect the female connector of the RS-232 cable directly to the
Console/Comm Port on the switch, and tighten the captive retaining
screws (see Figure 2-7
).
Figure 2-7. Connecting to the Console/Comm Port
4.
Connect the other end of the cable to a terminal or the serial connector of
a personal computer running communications software.
5.
Proceed to the next section, Connecting Power, to connect the AC
power cord and power up the BayStack 410-24T switch.