Page 1 - Installation

Nortel CallPilot1005r Server HardwareInstallationNN44200-308.

Page 2 - Trademarks

10 Chapter 1 How to get helpwww.nortel.com/ercGetting Help through a Nortel distributor or resellerIf you purchased a service contract for your Nortel

Page 3 - Information for Japan

11Chapter 21005r server descriptionIn this chapter"1005r Server features" (page 11)"Valid PCI card configurations" (page 16)"N

Page 4

12 Chapter 2 1005r server descriptionServer dimensions and weightHeight 87.6 mm (3.45 in.)Width 435.3 mm (17.4 in.)Depth (distance from front to back)

Page 5 - Publication History

1005r Server features 13Front panel controlsLabelControl or featureLabelControl or featureA Power switch L HDD1 activityB Reset switch M HDD0 activity

Page 6 - 6 Publication History

14 Chapter 2 1005r server descriptionBack panel controls and featuresLabelControl or featureLabelControl or featureA DB15 Telco alarm connector(not us

Page 7 - Contents

1005r Server features 15PCI riser cardThe following picture shows the PCI riser assembly when removed from the1005r chassis. The PCI riser assembly is

Page 8 - 8 Contents

16 Chapter 2 1005r server descriptionPCI riser card (turned over)CAUTIONRisk of physical equipment damageRemove the 1005r from the rack, and place it

Page 9 - How to get help

Valid PCI card configurations 17Note: Your server configuration depends on what was ordered fromNortel. Therefore, your server may not have all of the s

Page 10 - 10 Chapter 1 How to get help

18 Chapter 2 1005r server descriptionConfigurationCardslottypeSlotnumber Position Card typeMeridian 1*/CS* 1000FS_PCI-1topMPB96 MGate 1, 2, 3FS_PCI-2

Page 11 - 1005r server description

Network connectivity 19Sample network setup: Communication Server 1000The following diagram shows a CallPilot server network setup with aCommunication

Page 12 - Environmental specifications

Document status: StandardDocument version: 01.06Document date: 15 May 2008Copyright © 2006-2008, Nortel NetworksAll Rights Reserved.Sourced in CanadaT

Page 13 - NN44200-308 01.06 Standard

20 Chapter 2 1005r server descriptionIn the previous illustration, the telephony LAN (TLAN subnet) providesIP connectivity between the CS 1000 system

Page 14 - PCI riser assembly

Supported peripheral devices 21Remote access connectivityUse one of the USB connectors on the rear of the 1005r server to connectto an external plug-a

Page 15 - PCI riser card

22 Chapter 2 1005r server descriptionNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Copyright © 2006-2008,

Page 16 - Valid PCI card configurations

23Chapter 3Preparing for installationIn this chapter•"Installation overview" (page 23)•"Unpacking the 1005r server" (page 25)• &qu

Page 17 - ATTENTION

24 Chapter 3 Preparing for installationStepDescriptionCheck2Unpack the server, and ensure you have all the items you need (see"Unpacking the 1005

Page 18 - Network connectivity

Unpacking the 1005r server 25StepDescriptionCheck•Install the software feature dongle (see "Installing the Nortelsoftware feature dongle" (p

Page 19 - Network connectivity 19

26 Chapter 3 Preparing for installationWARNINGRisk of personal injuryThe 1005r CallPilot server weighs approximately 20 kg (44 lb)when it is shipped f

Page 20 - Network requirements

Removing the front bezel 27Removing the front bezelIntroductionTo access the hard drives on the front panel, you must remove the frontbezel.The front

Page 21 - Supported peripheral devices

28 Chapter 3 Preparing for installation3Do not touch components on the front panel without ESD protection.Attach an ESD strap to your wrist and connec

Page 22

29Chapter 4Installing the server and peripheraldevicesIn this chapter"Installing the server" (page 29)"Installing a High Availability s

Page 23 - Preparing for installation

RADISYS is a trademark of Radisys Cor poration.SLR4, SLR5, and TANDBERG are trademarks of Tandberg Data ASA.SYBASE is a trademark of Sybase, Inc.TEAC

Page 24

30 Chapter 4 Installing the server and peripheral devicesATTENTIONThe 1005r server is supplied with industry standard 48.3 cm (19 in.) rack rails that

Page 25 - Unpacking the 1005r server

Connecting peripherals to the server 31•The two servers are delivered with only one dongle. It does not matterwhich server you connect the dongle to u

Page 26 - What is next?

32 Chapter 4 Installing the server and peripheral devicesLabelControl or featureLabelControl or featureB1 PCI card #3 dual NIC forHA configuration. Fo

Page 27 - Removing the front bezel

Connecting peripherals to the server 33To connect the modem to the serverStep Action1 Connect one end of the telephone cable to the modem RJ-11 jackla

Page 28

34 Chapter 4 Installing the server and peripheral devicesSLR75 tape drive installed on 1005r6The tape drive is plug-and-play and the required drivers

Page 29 - Chapter 4

Connecting the server to the ELAN subnet 35Connecting the server to the ELAN subnetIntroductionConnect the CallPilot server to the Meridian 1 switch o

Page 30

36 Chapter 4 Installing the server and peripheral devices—End—What is next?IF the server is THENconnected to a Nortel server subnet continue with &quo

Page 31 - Inspecting the modem

Installing the Nortel software feature dongle 37What is next?Continue with "Installing the Nortel software feature dongle" (page 37).Install

Page 32

38 Chapter 4 Installing the server and peripheral devicesfeature key with the data contact facing down and away from theembossed i. See "Installi

Page 33

Installing the Nortel software feature dongle 39What is next?Continue with Chapter 5 " Connecting the server to power" (page 41).Nortel Call

Page 35 - Introduction

40 Chapter 4 Installing the server and peripheral devicesNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Co

Page 36

41Chapter 5Connecting the server to powerIn this chapter•"Safety precautions" (page 41)•"Locating the power supply modules" (page

Page 37

42 Chapter 5 Connecting the server to power1005r rear panelAbout the power supply moduleAfter you power up the server (later in this guide), the power

Page 38 - Installing the. feature key

Connecting the server to power 43Provide a sufficient number of properly grounded power outlets or powerbars for all equipment. For more information, r

Page 39

44 Chapter 5 Connecting the server to powerTo connect the 1005r AC server to powerStep ActionWARNINGRisk of personal injury, risk of hardware failureT

Page 40

Connecting the server to power 457Use the wizard to configure your system. For further details, see theInstallation and Configuration Task List (NN44200

Page 41 - Chapter 5

46 Chapter 5 Connecting the server to powerNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Copyright © 2006

Page 42 - Before you begin

47Appendix AEMC emission level protection for the1005r ServerTo lower the EMC emission level, ferrite cores are installed with one loop(see the follow

Page 43 - 1005r server in a network

48 Appendix A EMC emission level protection for the 1005r ServerFerrite cores secured to an external cableThe ferrite cores are secured to the appropr

Page 44 - To start the server

49IndexSymbols/Numerics1005r serverback panel 13dimensions and weight 12ELANconnection, establishing 35environmental specifications 12front bezelremovi

Page 45

5Publication HistoryMay 2008CallPilot 5.0, Standard 01.06 of CallPilot Installation and Configuration,1005r Server Hardware Installation is issued for

Page 46

50 Indexenvironmental specifications 12equipmentunpacking 26Ethernet hubdescription 21Ffax modemrequired equipment 31featuresserver 11features, front p

Page 47 - 1005r Server

Index 51power connection 42serial number 37slotassignments 16configurationsoftware feature key 37specifications, environmental 12Ttelephony LANSee TLAN

Page 48

52 IndexNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Copyright © 2006-2008, Nortel Networks.

Page 50 - 50 Index

Nortel CallPilot1005r Server Hardware InstallationCopyright © 2006-2008, Nortel NetworksAll Rights Reserved.Publication: NN44200-308Document status: S

Page 51 - Index 51

6 Publication HistoryNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Copyright © 2006-2008, Nortel Networks

Page 52 - 52 Index

7ContentsChapter 1 How to get help 9Chapter 2 1005r server description 111005r Server features 11Valid PCI card configurations 16Network connectivity 1

Page 53

8 ContentsNortel CallPilot1005r Server Hardware InstallationNN44200-308 01.06 Standard5.0 15 May 2008Copyright © 2006-2008, Nortel Networks.

Page 54

9Chapter 1How to get helpThis section explains how to get help for Nortel products and services.Getting Help from the Nortel Web siteThe best way to g

Commentaires sur ces manuels

Pas de commentaire