Installing the firmware upgrades 107
Procedure Steps
Step Action
1
Load the hard drive firmware upgrade CD into the CD-ROM
drive.
2 Log on to the server as the SSA role (ntsysadm).
3
Reboot the server.
sudo reboot
4
If the operating system has been installed, change the boot
sequence so that the CD-ROM is the primary boot device by
doing the following:
When the BIOS information appears, press F12 to select the
boot sequence.
Select CD-ROM as the primary boot device.
Otherwise, wait for the server to reboot.
The ServeRAID Manager Hard Drive Update screen appears.
5 If an upgrade is required, press Enter to apply the upgrade.
The hard drive firmware upgrade is installed.
Otherwise, press Enter and go to step 7.
6
Select OK twice to complete the upgrade.
Attention: Do not power off the system during the upgrade.
7
When the update completes, remove the CD from the CD-ROM
drive and select OK to boot the operating system.
--End--
Installing ServeRAID firmware upgrades
Use this procedure to install ServeRAID firmware upgrades. This
procedure requires the reboot of the server.
Prerequisites
You must be assigned to the SSA role (ntsysadm).
You must have the CD containing the ServeRAID firmware upgrade
file.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300 01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.