Vue de la page 151
RAID operations Standard 1.10
152 CallPilot
Requirements
Phillips (cross head) screwdriver, #1 and #2 bit
RAID card replacement kit
electrostatic discharge (ESD) grounding strap
To replace the RAID card
1 Power down the server, unplug all peripheral devices and ethernet
cables, and disconnect the AC power.
2 Attach the ESD strap to your wrist and attach the other end to a
grounded connection away from the server.
3 Remove the chassis cover. Refer to “Removing and replacing the
server cover” on page 108 for instructions.
4 Disconnect the red power cable from the PCI riser assembly.
5 Disconnect the DS30X cable from the MPB96 card in the full-size
side of the PCI riser.