Replacing basic chassis components Standard 1.10
132 CallPilot
Replacing memory DIMMs
Four Dual Inline Memory Modules (DIMMs) are installed on your
server. You must replace all four memory DIMMs with those in the
Nortel replacement pack. Nortel does not support more than four DIMM
modules in the 1005r server.
To replace the DIMM cards
1 Power down the server, unplug all peripheral devices and Ethernet
cables, and disconnect the AC power.
2 Attach the ESD strap to your wrist and attach the other end to a
known grounded connection.
3 Remove the chassis cover. Refer to “Removing and replacing the
server cover” on page 108 for instructions.
4 Remove the processor air duct. Refer to “To remove the processor
air duct” on page 110 for instruction.
5 Locate memory banks 1A, 1B, 2A, and 2B on the server board.
Refer to the following diagram.
.
CAUTION
Risk of equipment damage
Take precautions to protect internal components. Electrostatic
discharge (ESD) can damage cards and make them unusable.