Chapter 6 CLI Procedure for Creating a Node Profile
53
Getting Started with Passport 4400, Release 4.1
Defining Node ID
To define a node ID, use the following CLI command:
CLI> define msm profile nodeID
Example:
CLI> define msm profile nodeID 23
If you dont want to modify any more parameters in this window, go to Saving
the Current Configuration and Resetting the Unit on page 54, or continue with
Defining Customer ID on page 53.
Defining Customer ID
To define a customer ID, use the following CLI command:
CLI> define msm profile customerID
Parameter Range of Value Required Action
<NodeID> INTEGER (1..65535) Enter an integer between 1 and
65535. If your network uses node
IDs to identify Passport 4460 units,
be sure to assign each unit a unique
node ID.
Note:
The element msm signifies the MPANL signal mechanism. The
customer ID is expressed as an integer between 0 and 65535. The terms
MPANL and PANL both refer to the same protocol and may be used
interchangeably.
Parameter Range of Value Required Action
<CustomerID> INTEGER (0..65535) Enter an integer between 1 and
65535.