Cabling network modules and loops Page 251 of 456
Communication Server 1000M and Meridian 1 Large System Installation and Commissioning
Refer to Table 32 on page 248 for cCNI port and slot assignments. Connect
Shelf 0 3PE cards to the Core/Net 0 panel; connect Shelf 1 3PE cards to the
Core/Net 1 panel. The 3PE cables for Network Group 0 are factory installed.
Procedure 41
Connecting the Network Shelf 0 3PE cards to Core/Net 0
1 Connect a NTND14 cable of the appropriate length from J3 on the 3PE
card faceplate in Network Group 1, Shelf 0 to the Port 9-1, J3 connection
on the 3PE Fanout panel in Core/Net 0.
2 Connect a NTND14 cable of the appropriate length from J4 on the 3PE
card faceplate in Network Group 1, Shelf 0 to the Port 9-1, J4 connection
on the 3PE Fanout panel in Core/Net 0.
3 Connect a NTND14 cable of the appropriate length from J3 on the 3PE
card faceplate in Network Group 2, Shelf 0 to the Port 10-0, J3 connection
on the 3PE Fanout panel in Core/Net 0.
4 Connect a NTND14 cable of the appropriate length from J4 on the 3PE
card faceplate in Network Group 2, Shelf 0 to the Port 10-0, J4 connection
on the 3PE Fanout panel in Core/Net 0.
5 Install the remaining cables according to the assignments in Table 32 on
page 248.
End of Procedure
Procedure 42
Connecting the Network Shelf 1 3PE cards to Core/Net 1
1 Connect a NTND14 cable of the appropriate length from J3 on the 3PE
card faceplate in Network Group 1, Shelf 1 to the Port 9-1, J3 connection
on the 3PE Fanout panel in Core/Net 1.
2 Connect a NTND14 cable of the appropriate length from J4 on the 3PE
card faceplate in Network Group 1, Shelf 1 to the Port 9-1, J4 connection
on the 3PE Fanout panel in Core/Net 1.
3 Connect a NTND14 cable of the appropriate length from J3 on the 3PE
card faceplate in Network Group 2, Shelf 1 to the Port 10-0, J3 connection
on the 3PE Fanout panel in Core/Net 1.
4 Connect a NTND14 cable of the appropriate length from J4 on the 3PE
card faceplate in Network Group 2, Shelf 1 to the Port 10-0, J4 connection
on the 3PE Fanout panel in Core/Net 1.