Alteon OS Application Guide
222
Chapter 13: High Availability 42C4911, January 2007
Figure 13-3 shows a configuration with two trunks. VLAN Monitor is turned off, so only one
Failover Trigger is configured on each switch. GbESM 1 is the primary switch for Server 1 and
Server 2. GbESM 2 is the primary switch for Server 3 and Server 4. STP is turned off.
If all links in trigger 1 go down, GbESM 1 disables all internal links to server blades.
Figure 13-3 Two trunks, one Failover Trigger
Internet
Internet
Enterprise
Routing Switch
GbESM 1
GbESM 2
Trigger 1
Trigger 1
BladeCenter
Server
1
VLAN 1:
VLAN 2:
VLAN Monitor = O
ffOff
Server
3
Server
2
Server
4