Option settings Page 153 of 906
Circuit Card Description and Installation
QPC841 4-Port Serial Data Interface card
Tables 60 through 62 list option settings for the QPC841 4-Port SDI card.
Table 60
QPC841 port 1 and 2 address selection
Device number SW14
Port 1 Port 2 1 2 3 4 5 6 7 8
0 1 off off off off off on on on
2 3 off off off off off on on off
4 5 off off off off off on off on
6 7 off off off off off on off off
8 9 off off off off off off on on
10 11 off off off off off off on off
12 13 off off off off off off off on
14 15 off off off off off off off off
Note 1: On SW16, positions 1, 2, 3, and 4 must be OFF.
Note 2: To avoid address conflicts, SW14 and SW15 can never have identical setting.
Note 3: To disable ports 1 and 2, set SW14 position 1 to ON.