Host error messages
A-3
Meridian IVR VT100 Gateway Development Guide Product release 2.0/I
ERR: All available sessions are non-operational
Meaning:
None of the sessions is operational.
Action to take:
Make sure the communication board has been downloaded
correctly. The download command should be included in
.profile file.
ERR: xx Sessions are Operational
Meaning:
TRS found that xx sessions are operational.
Action to take:
Check to see if the number matches the defined number of
sessions in the trs.conf file.
ERR: BD xx SS xx Failure to create process object
Meaning:
TRS was unable to allocate memory for the process
structure for board xx session xx.
Action to take:
Contact your Nortel service representative.
ERR: Unable to create Board Object Instance
Meaning:
TRS was unable to allocate memory for the board object
structure.
Action to take:
Contact your Nortel service representative.
ERR: Unable to create Session Object Instance
Meaning:
TRS was unable to allocate memory for the session object
structure.
Action to take:
Contact your Nortel service representative.
ERR: Unable to create Process Object Instance
Meaning:
TRS was unable to allocate memory for the project object
structure.
Action to take:
Contact your Nortel service representative.
ERR: Unable to create Application Object
Meaning:
TRS was unable to allocate memory for the application
object structure.